Newsline

Tag archive: vertical test

New type of thermal sensors for vertical testing of nine-cell cavities for the ILC

8 October 2009 Scientists at Kyoto university are testing a new type of thermal sensor for superconducting cavities on the vertical test for ILC at the Superconducting radiofrequency Test Facility (STF) at KEK. This sensor is under development by a Kyoto-KEK collaboration The team is developing this new device to address issues in the components of the sensor – tangled wires and resistors. At STF, a carbon resistor is used for vertical testing of nine-cell cavities. They have already installed 350 sensors on the outer surface of the nine-cell cavity, and 700 lead wires were needed to connect both ends of sensors through cryogenic area and outside, in order to measure the temperature. “For a shorter developing time, I have chosen carbon resistor which is technologically proven in the past superconducting cavity R&D. This structure is simple, not so sophisticated.” said Yasuchika 'Kirk' Yamamoto, the scientist at KEK who designed the present system. When the cavity is being tested, it is cooled to 2 kelvins, and has to stay at that temperature as much as possible. In general, it is best to use the smallest possible number of lead wires to prevent heat invasion to the cryogenic area. “The current system needs too many lead wires, and the production of the carbon resistor has been discontinued, we thought we should develop a new thermal sensor to replace it,” he said. Category: Around the World | Tagged: , , ,